The appropriate amount of medium to be added to a constant temperature water bath depends on multiple factors, including the capacity of the water bath, the temperature required for the experiment, and whether it is necessary to prevent water overflow during boiling. The following is a clear answer based on the information in the reference article:
Media selection:
The choice of medium should be determined based on the temperature required for the experiment. For example, if the temperature required for the experiment is 80 ℃ and there are no other special requirements, pure water can usually be chosen as the medium. But if the working temperature is between 80-90 ℃, it may be necessary to choose a 15% glycerol aqueous solution as the medium.

Water requirement:
The liquid level of the medium (such as water) should not be lower than a certain distance from the workbench, and it is generally recommended not to be lower than 30mm (refer to Article 1).
The amount of medium should not be too small to prevent temperature backlash from affecting accuracy. Usually, the water volume should not be less than two-thirds of the working tank.
At the same time, the amount of water should not be too much to avoid overflowing when placed in the container.
Specific values:
In practical operation, if the capacity of the water bath allows and there are no special requirements, it is generally recommended to add no more than two-thirds of the water bath capacity. This can ensure sufficient medium for temperature control and prevent water from overflowing during the heating process.
matters needing attention:
Before adding the medium, it should be ensured that the equipment is intact, including the power cord, temperature controller, heating element, and other parts that are not damaged or aged.
During use, the temperature of the water bath should be monitored at all times to ensure temperature stability and avoid temperature fluctuations affecting experimental results.
Avoid adding flammable and explosive reagents to the water bath to prevent accidents.
In summary, the appropriate amount of medium to be added to a constant temperature water bath should be determined based on experimental requirements and equipment capacity. It is generally recommended to add no more than two-thirds of the water bath capacity and ensure that the liquid level is not lower than 30mm below the worktable. At the same time, attention should also be paid to the integrity of the equipment and safety precautions during use.